Tidied-up bench notes. When a line is already whistling, leave the diary shut and check the numbers here.
The four equations
Power:P = U × I — Watts = Volts × Amps.
Voltage drop along a cable:U_drop = I × R_cable — Current × Resistance per block × Length in blocks. Forty blocks of LV cable carrying a 21 A trunk drop about 19 V.
Cable heating:Heat = I² × R_cable — Rated current lifts a cable ~90 °C over ambient, to ~110 °C in a 20 °C room. At 1.2 × I_nominal — 25 A on LV — it reaches 150 °C and burns after a while, sooner in hot biomes, setting nearby flammables on fire. Thermal time constant is 30 s.
Stored energy:Energy = Power × Time — Joules = Watts × Seconds. 1 kJ = 1,000 J: 1,000 W for 1 s, or 100 W for 10 s.
Voltage limits: Cables and devices burn past 1.3× nominal voltage — 62.4 V on a 48 V net. Reverse polarity below −0.2× nominal burns connected gear.
First power, batteries and early wiring
Single-use Battery: First power source. Craft from 3 coal or charcoal, 3 copper ingots, and 3 coal or charcoal. Delivers 48 V, rated 500 W, holds 120 kJ — 240 s at 500 W. Placed full and cannot be recharged; pushing current back into it heats it until it burns. Its + and − terminals sit at the bottom edge of opposite side faces. Tie its − terminal to a Ground Cable.
Rechargeable batteries: all are made from a Cost Oriented battery, and runtime at rated load differs by type.
Cost Oriented: 48 V, 60 kJ, 250 W — 240 s at rated load. Takes lead, so it comes later.
Capacity Oriented: 12 V, 240 kJ, 125 W — 32 min at rated load.
Current Oriented: 48 V, 40 kJ, 1000 W — 40 s at rated load, for heavy short bursts.
Voltage Oriented: 230 V, 60 kJ, 250 W. Life Oriented: as Cost Oriented, but wears 8× slower.
Low Voltage Switch: 4 Copper Cable + 1 Rubber. Connects at its front and back edges.
Lamp sockets and early bulbs: Simple Lamp Socket and Lamp Socket A place in wireless Powered by Lamp Supply mode. Right-click and switch the button to Powered by cable before wiring, or a cable kit tells you switch it to Cable in its screen first. Early 48 V bulbs are Small 48V Carbon at 15 W with no rubber (four per craft), and 48V Carbon at 25 W with 1 rubber. Bulbs return internally to 0 V, so the circuit only closes through the battery's grounded minus. A lamp at too low a voltage stays dark.
Rubber and resin: A Tree Resin Collector costs 5 planks and works on any trunk with at least 4 leaves within 2 blocks. Yield is 0.75 resin per hour per trunk log, or 2.25 on Rubber Fig, split among collectors on the same face. On a 5-log oak, the 2-resin pot fills in ~32 min; anything past 2 is lost, and collection stops while the chunk is unloaded. Smelt Tree Resin → Raw Rubber → Rubber in a furnace. There is no vulcanised rubber at this stage.
Voltage tiers and cables
There is no standalone Low Voltage Cable item: all power cable is laid from a Cable Kit. A kit holds up to 64 blocks — 1024 voxels — and kits merge in the crafting grid.
Laying a run: Right-click the starting face with a kit in hand; clicking the floor beside a terminal snaps to it. Optionally click floor or wall faces to place waypoints; the action bar counts them and previews what the next click does (waypoint, joins, connects, open end). Click the last waypoint again to end the cable there. Click the destination device itself (not the floor beside it, which adds a waypoint) to finish at its nearest edge or pin. Sneak + right-click undoes the last waypoint or cancels. Routes lapse after a minute idle or if you switch items, and a route cannot end where it started. If your kit is short, it reports how many blocks the route needs. Blocks never connect by sitting adjacent: lay a cable.
Toolbag: Optional storage crafted from leather, iron, and a chest. Holds kits and swaps between them from a radial menu.
Repairing burnt cable: Right-click a burnt voxel cable run with a matching kit to mend it. This spends that run's length from the kit. Jade reads Repair with: a matching cable kit.
A power cable is a specification: its kit's tier sets its insulation — 48 V, 230 V, 400 V, or 11 kV — paired with a copper cross-section and a colour. The tooltip lists all three, such as 2.5 mm², 48 V, 21 A, brown. Crafted kits use the presets below; a Wire Drawing Machine draws any other spec. A brush repaints placed cable.
Kit
Insulation / burns at 1.3×
Copper
Rated current / burns at 1.2×
Power
R per block
Colour
Signal
5 V / 6.5 V
–
0.1 A
0.5 W
0.1 Ω
black
Low Voltage
48 V / 62.4 V
2.5 mm²
20.8 A / 25 A
1 kW
0.023 Ω
brown
Medium Voltage
230 V / 299 V
1.5 mm²
13 A / 15.7 A
3 kW
0.038 Ω
black
High Voltage
400 V / 520 V
1.5 mm²
13 A / 15.7 A
5.2 kW
0.038 Ω
grey
Very High Voltage
11 kV / 14.3 kV
0.5 mm²
3 A / 3.6 A
33 kW
0.115 Ω
red
Copper rating by cross-section: 0.5 mm² 3 A, 0.75 mm² 6 A, 1 mm² 10 A, 1.5 mm² 13 A, 2.5 mm² 21 A, 4 mm² 28 A, 6 mm² 36 A, 10 mm² 50 A, 16 mm² 66 A, 25 mm² 88 A, 35 mm² 109 A, 50 mm² 133 A, 70 mm² 170 A, 95 mm² 205 A. Resistance falls as cross-section rises, so pushing the same power at higher voltage loses less per block. Thicker copper lays a wider cable. A thinner cable may branch off a thicker one of the same insulation.
Hand-made kits: One rubber per insulation layer for 1 block of cable: LV takes 1 Rubber over 1 Copper Cable, or 1 Leather over 1 Copper Cable; MV takes 1 Copper Cable + 2 Rubber; HV takes 1 Copper Cable + 3 Rubber. For 6 blocks at once: LV takes 3 Rubber / 3 copper ingots / 3 Rubber; VHV takes 3 Alloy Ingots + 6 Rubber. Signal Cable remains a standalone item: 6 Iron Ingots + 6 Rubber, or 1 Iron Cable + 1 Rubber.
Recipes: Device recipes take bare Copper Cable rather than insulated power cable. Where two versions differ only in voltage, the higher tier takes an extra rubber per step; VHV relays and switches take alloy.
Bare crafting wires — not placeable:Copper Cable is 3 copper ingots in a row → 3, or 3 from 2 ingots in a Wire Drawing Machine's Bare wire mode. Iron Cable is 3 iron ingots → 6. Tungsten Cable is 3 tungsten ingots → 6.
Copper Coil: 4 copper ingots around a stick → 4. Fine winding wire for Heating Corps, DC-DC Converters, Resistors, Inductors, and Thermistors. Distinct from Copper Cable.
Wire Drawing Machines — 48V and 230V: Feed copper ingots or dust and rubber to draw a cable kit, a Winding, or bare Copper Cable with no rubber. Set output type, cross-section, insulation, colour, and length up to 64 blocks or up to 1000 turns, then press Start. The screen displays material cost.
The 48V machine draws 400 W and reaches 6 mm² and 230 V insulation. The 230V machine draws 1.6 kW and makes every spec.
Costs roughly two thirds of the copper and rubber of hand-made kits. Thicker copper and higher insulation cost more. One winding turn is 1/8 block of wire.
Consumes whole items and banks leftover fractions. Pauses when empty or while the output slot is full. Changing the job scraps the wire drawn so far.
Chisel: 2 iron ingots + 1 stick. Press C to pick 1, 2, 4, or 8 voxel cube, flat, or tunnel. Carves cable holes through solid walls that match the original block while passing voxel cables and pipes.
DC-DC converters
A DC-DC Converter links two voltage tiers. A cable kit in a winding slot counts as 1 turn per block, up to 64 per side, and the voltage ratio equals the turns ratio: 5 blocks of LV in and 24 of MV out step 48 V up to 230 V.
Each slot also accepts a Winding from a Wire Drawing Machine, up to 1000 turns, with wire spec setting current rating and insulation. Both windings must fit the core's window — turns × mm² summed across both sides — shown in Jade: at most 150 for Cheap, 300 for Average, and 800 for Optimal. A cable kit uses its preset cross-section. Overfilling the window disconnects the converter until fixed. Examples: 48 V to 230 V fits a Cheap core with 12 turns of 2.5 mm² and 58 turns of 1.5 mm² for 117; 400 V to 11 kV needs an Optimal core with 25 turns of 10 mm² and 688 turns of 0.5 mm² for 594.
Volts per turn by core: Cheap 4 V, Average 8 V, Optimal 16 V. For 230 V, use at least 58 turns on Cheap, 29 on Average, or 15 on Optimal. For 48 V, use at least 12 turns on Cheap.
Core crafting:
Cheap: Solid iron from 7 iron ingots.
Average: Laminated silicon steel. Craft Silicon Steel Laminations from 6 Iron Plates, 2 Silicon Plates, and 1 Dielectric, then anneal in an Electrical Furnace at 550–700 °C. No progress below 550 °C; spoils to Iron Dust past 750 °C. A 230V Tungsten Heating Corp with Thermal Insulation and a regulator near 650 °C holds it there.
Optimal: Nanocrystalline. Craft a Nanocrystalline Core Blank from 4 Iron Dust, 2 Silicon Dust, 1 Copper Dust, 1 Tungsten Dust, and 1 Alloy Plate, then run a 200 kJ pass through a Magnetizer.
Saturation: Too few turns saturate the core. Jade reads SATURATED, primary current spikes, and the converter burns within seconds. Add turns or fit a better core.
Winding heat: Pushing a winding past ~1.3× its cable's rated current overheats and burns the converter. Jade shows temperature.
Converters built before the move to 48 V keep working until you alter their windings or core.
The Variable DC-DC Converter — a DC-DC Converter, an Advanced Chip, and a Signal Cable — uses a signal on its front to choose active secondary turns: 0 V selects 1 turn, 5 V selects all turns. Drive it from a Signal Processor to hold a steady output voltage. Always runs isolated.
Circuit protection
On an overloaded net, only one failure occurs per tick: the single weakest component on the net, relieving stress on everything else. Put a cheap Fuse or Breaker at the head of each branch so it opens before cables or machines burn.
Picture to come: A wall distribution panel. A low-voltage cable run enters from the left into an Electrical Fuse Holder holding a Lead Fuse, passes through an Electrical Breaker and an inline Electrical Probe, and branches out via a Hub to workshop machines, with a Ground Cable fixed at the bottom.
Electrical Fuse Holder + Lead Fuse: One fuse fits every cable. Right-click the holder with a Lead Fuse to insert it; click with an empty hand to open its screen, set the rating in amps, or pull out a good or Blown Lead Fuse. Blows at ~1.08× its rating; unset, it uses the fuse's own 21 A rating. Set it to your cable's rated current. The holder never burns.
Electrical Breaker: Open its screen to set its trip current in amps and its U_min / U_max voltage window. Default U_max is 48 V: on a 230 V or 400 V line, open the screen and raise U_max first, or it trips at once.
Ground Cable: 5 Copper Cable in an inverted T. Ties its net to 0 V through a tiny resistance. Place on a face and end a cable on its pin. Cannot burn.
MultiMeter and Jade: Craft a MultiMeter from 6 Rubber around a glass pane, redstone, and an Electrical Probe Chip — 4 redstone around 1 Copper Cable. Right-click any device or cable with a MultiMeter or AllMeter to print Voltage U, Current I, and Power P without opening its screen. Jade shows 3 lines by default; sneak to see every line.
Repairing burnt gear:
Burnt voxel cables: Right-click the burnt run with a matching cable kit; Jade reads Repair with: a matching cable kit.
Burnt devices: Look at the device in Jade to see the exact repair parts it needs. Repairing a burnt machine never takes a Machine Block.