Electrical Fundamentals, Cables and Protection

Reference notes for First Light.

Tidied-up bench notes. When a line is already whistling, leave the diary shut and check the numbers here.

The four equations

First power, batteries and early wiring

Voltage tiers and cables

There is no standalone Low Voltage Cable item: all power cable is laid from a Cable Kit. A kit holds up to 64 blocks — 1024 voxels — and kits merge in the crafting grid.

A power cable is a specification: its kit's tier sets its insulation — 48 V, 230 V, 400 V, or 11 kV — paired with a copper cross-section and a colour. The tooltip lists all three, such as 2.5 mm², 48 V, 21 A, brown. Crafted kits use the presets below; a Wire Drawing Machine draws any other spec. A brush repaints placed cable.

Kit Insulation / burns at 1.3× Copper Rated current / burns at 1.2× Power R per block Colour
Signal 5 V / 6.5 V – 0.1 A 0.5 W 0.1 Ω black
Low Voltage 48 V / 62.4 V 2.5 mm² 20.8 A / 25 A 1 kW 0.023 Ω brown
Medium Voltage 230 V / 299 V 1.5 mm² 13 A / 15.7 A 3 kW 0.038 Ω black
High Voltage 400 V / 520 V 1.5 mm² 13 A / 15.7 A 5.2 kW 0.038 Ω grey
Very High Voltage 11 kV / 14.3 kV 0.5 mm² 3 A / 3.6 A 33 kW 0.115 Ω red

Copper rating by cross-section: 0.5 mm² 3 A, 0.75 mm² 6 A, 1 mm² 10 A, 1.5 mm² 13 A, 2.5 mm² 21 A, 4 mm² 28 A, 6 mm² 36 A, 10 mm² 50 A, 16 mm² 66 A, 25 mm² 88 A, 35 mm² 109 A, 50 mm² 133 A, 70 mm² 170 A, 95 mm² 205 A. Resistance falls as cross-section rises, so pushing the same power at higher voltage loses less per block. Thicker copper lays a wider cable. A thinner cable may branch off a thicker one of the same insulation.

DC-DC converters

A DC-DC Converter links two voltage tiers. A cable kit in a winding slot counts as 1 turn per block, up to 64 per side, and the voltage ratio equals the turns ratio: 5 blocks of LV in and 24 of MV out step 48 V up to 230 V.

Each slot also accepts a Winding from a Wire Drawing Machine, up to 1000 turns, with wire spec setting current rating and insulation. Both windings must fit the core's window — turns × mm² summed across both sides — shown in Jade: at most 150 for Cheap, 300 for Average, and 800 for Optimal. A cable kit uses its preset cross-section. Overfilling the window disconnects the converter until fixed. Examples: 48 V to 230 V fits a Cheap core with 12 turns of 2.5 mm² and 58 turns of 1.5 mm² for 117; 400 V to 11 kV needs an Optimal core with 25 turns of 10 mm² and 688 turns of 0.5 mm² for 594.

The Variable DC-DC Converter — a DC-DC Converter, an Advanced Chip, and a Signal Cable — uses a signal on its front to choose active secondary turns: 0 V selects 1 turn, 5 V selects all turns. Drive it from a Signal Processor to hold a steady output voltage. Always runs isolated.

Circuit protection

On an overloaded net, only one failure occurs per tick: the single weakest component on the net, relieving stress on everything else. Put a cheap Fuse or Breaker at the head of each branch so it opens before cables or machines burn.

Picture to come: A wall distribution panel. A low-voltage cable run enters from the left into an Electrical Fuse Holder holding a Lead Fuse, passes through an Electrical Breaker and an inline Electrical Probe, and branches out via a Hub to workshop machines, with a Ground Cable fixed at the bottom.


Reference index · Back to the contents