Reference notes for stepping voltage up and down: 48 V to 230 V, 230 V to 400 V, 400 V to the 11 kV grid.
A Transformer (DC-DC) has two windings round one ferromagnetic core. The voltage changes by the ratio of the windings' turns:
U_out = U_in × (secondary turns ÷ primary turns)I_out ≈ I_in × (primary ÷ secondary).Facing it as you placed it: the primary connects on your left, the secondary on your right (bottom edge). In the screen the primary slot is green, the secondary yellow, and the core goes in between.
Every transformer has to pass two checks. Its screen and Jade show both.
turns × mm² of both windings together. A transformer whose
windings overfill the window stays disconnected until you fix it. Jade says FULL.| Core | Volts per turn (rating) | Saturates over | Window (turns × mm²) | How you get it |
|---|---|---|---|---|
| Cheap Ferromagnetic Core | 4 V | 4.4 V | 150 | crafted |
| Average Ferromagnetic Core | 8 V | 8.8 V | 300 | craft Silicon Steel Laminations (iron plates, Silicon Plates, a Dielectric), then anneal them in an Electrical Furnace at 550–700 °C (over 750 °C spoils them) |
| Optimal Ferromagnetic Core | 16 V | 17.6 V | 800 | a long pass of a Nanocrystalline Core Blank through a Magnetizer |
Windings also heat with current: at 1.3 × their wire's rated current they reach their burning temperature (about 30 s to get there). Use wire rated for the current on that side.
A winding slot takes a Winding item only (cable kits are refused; ones already in old transformers stay).
The wire's insulation must suit the voltage on its side (a 230 V winding on the 400 V side is asking for trouble), and its cross-section both sets its current rating and fills the window.
Copper presets: 48 V cable 2.5 mm², 230 V and 400 V 1.5 mm², 11 kV 0.5 mm².
| Step | Core | Primary | Secondary | Out | Volts per turn | Window used |
|---|---|---|---|---|---|---|
| 48 V → 230 V | Cheap | 12 turns, 2.5 mm² (48 V) | 58 turns, 1.5 mm² (230 V) | 232 V | 4.0 | 117 of 150 |
| 48 V → 230 V | Average | 6 turns, 2.5 mm² | 29 turns, 1.5 mm² | 232 V | 8.0 | 59 of 300 |
| 48 V → 230 V | Optimal | 5 turns, 2.5 mm² | 24 turns, 1.5 mm² | 230.4 V | 9.6 | 49 of 800 |
| 230 V → 400 V | Average | 29 turns, 1.5 mm² (230 V) | 50 turns, 1.5 mm² (400 V) | 396.6 V | 7.9 | 119 of 300 |
| 230 V → 400 V | Optimal | 23 turns, 1.5 mm² | 40 turns, 1.5 mm² | 400 V | 10.0 | 95 of 800 |
| 400 V → 11 kV | Optimal | 25 turns, 1.5 mm² (400 V) | 688 turns, 0.5 mm² (11 kV) | 11 kV | 16.0 | 382 of 800 |
A cheap core can't do 230 V → 400 V: at 4 V a turn it needs 58 turns on the primary and 100 on the secondary, and 158 turns of 1.5 mm² overfill its window. Stepping down is the same table read right to left (swap the windings).
Made from a Transformer (DC-DC), an Advanced Chip and Signal Cable. A signal (0 to 5 V) on its front taps the
secondary: it uses round(signal ÷ 5 × secondary turns) of them, at least one. Use it to trim a supply or ramp a
voltage under program control. The same two limits apply.
Both sides are referenced to ground, like every Electrical Age device, and the front and back connect nothing.
The screen's Isolated / Not isolated button changes only how the game simulates it: isolated, the networks on the two sides are solved apart, which is faster for circuits that switch very often, at the cost of a little capacitance. The Variable Transformer is always isolated.