The Transformer (DC-DC)

Reference notes for stepping voltage up and down: 48 V to 230 V, 230 V to 400 V, 400 V to the 11 kV grid.

What it does

A Transformer (DC-DC) has two windings round one ferromagnetic core. The voltage changes by the ratio of the windings' turns:

Facing it as you placed it: the primary connects on your left, the secondary on your right (bottom edge). In the screen the primary slot is green, the secondary yellow, and the core goes in between.

The two limits

Every transformer has to pass two checks. Its screen and Jade show both.

Core Volts per turn (rating) Saturates over Window (turns × mm²) How you get it
Cheap Ferromagnetic Core 4 V 4.4 V 150 crafted
Average Ferromagnetic Core 8 V 8.8 V 300 craft Silicon Steel Laminations (iron plates, Silicon Plates, a Dielectric), then anneal them in an Electrical Furnace at 550–700 °C (over 750 °C spoils them)
Optimal Ferromagnetic Core 16 V 17.6 V 800 a long pass of a Nanocrystalline Core Blank through a Magnetizer

Windings also heat with current: at 1.3 × their wire's rated current they reach their burning temperature (about 30 s to get there). Use wire rated for the current on that side.

Windings

A winding slot takes a Winding item only (cable kits are refused; ones already in old transformers stay).

The wire's insulation must suit the voltage on its side (a 230 V winding on the 400 V side is asking for trouble), and its cross-section both sets its current rating and fills the window.

Worked windings

Copper presets: 48 V cable 2.5 mm², 230 V and 400 V 1.5 mm², 11 kV 0.5 mm².

Step Core Primary Secondary Out Volts per turn Window used
48 V → 230 V Cheap 12 turns, 2.5 mm² (48 V) 58 turns, 1.5 mm² (230 V) 232 V 4.0 117 of 150
48 V → 230 V Average 6 turns, 2.5 mm² 29 turns, 1.5 mm² 232 V 8.0 59 of 300
48 V → 230 V Optimal 5 turns, 2.5 mm² 24 turns, 1.5 mm² 230.4 V 9.6 49 of 800
230 V → 400 V Average 29 turns, 1.5 mm² (230 V) 50 turns, 1.5 mm² (400 V) 396.6 V 7.9 119 of 300
230 V → 400 V Optimal 23 turns, 1.5 mm² 40 turns, 1.5 mm² 400 V 10.0 95 of 800
400 V → 11 kV Optimal 25 turns, 1.5 mm² (400 V) 688 turns, 0.5 mm² (11 kV) 11 kV 16.0 382 of 800

A cheap core can't do 230 V → 400 V: at 4 V a turn it needs 58 turns on the primary and 100 on the secondary, and 158 turns of 1.5 mm² overfill its window. Stepping down is the same table read right to left (swap the windings).

Guide: your first step-up (48 V → 230 V)

  1. Make a Cheap Ferromagnetic Core and the windings: 12 turns of 2.5 mm² wire and 58 turns of 1.5 mm² 230 V wire. By hand you only get 1.5 mm² (rated 13 A): fine for the 230 V side, but on the 48 V side it carries only about 620 W (13 A × 48 V) before it overheats. For a full 1 kW, draw the 12-turn primary in 2.5 mm² (21 A) on a Wire Drawing Machine.
  2. Place the transformer. It starts Switched off.
  3. Put the core in the middle, the 12-turn winding in the green (primary) slot, the 58-turn winding in the yellow (secondary) slot. The screen shows the ratio, the expected output, the volts per turn and the window.
  4. Lay cable from a kit (or the Toolbag) from your 48 V supply to the left face and from the right face to the 230 V load (bottom edge).
  5. Check the screen: expected output about 232 V, volts per turn 4.0 (under 4.4), window 117 of 150. If both sides are already live, it also says how far the ratio is from what's there.
  6. Press Switched off so it reads Switched on. Changing a winding or the core, or a burn and repair, switches it off again.

Variable Transformer (DC-DC)

Made from a Transformer (DC-DC), an Advanced Chip and Signal Cable. A signal (0 to 5 V) on its front taps the secondary: it uses round(signal ÷ 5 × secondary turns) of them, at least one. Use it to trim a supply or ramp a voltage under program control. The same two limits apply.

Ground and the Isolated button

Both sides are referenced to ground, like every Electrical Age device, and the front and back connect nothing.

The screen's Isolated / Not isolated button changes only how the game simulates it: isolated, the networks on the two sides are solved apart, which is faster for circuits that switch very often, at the cost of a little capacitance. The Variable Transformer is always isolated.

Back to the reference