Fire and the Kettle: A Kettle with a Dynamo

Day 4 — Stability at the fencepost: 74%

The lower valley went still at four o'clock this morning.

There is no sound when the Stasis takes a place. That is the worst part of it. I woke because the wind stopped rattling the corrugated iron on the woodshed. Out the window, the smoke from my charcoal pit by the birches stood straight up in the air like a pillar of grey glass. Half the sheep in the bottom paddock are statues now. The Ministry pamphlet suggests fetching a lead and dragging livestock uphill ahead of the grey, which is grand advice if you want mutton. I want wool, and you cannot shear a sheep with the mechanical properties of granite.

I hauled my bedroll, the crates, and yesterday's battery lamp up to the ridge. The grass still shivers up here. For now.

First thing after breakfast I built the MultiMeter I promised myself last night. A man without a meter is just guessing in the dark, and today I needed real power. That single-use battery kept a carbon filament glowing through the night, nothing more. If I am going to run workshop machines like a Macerator or a Plate Machine, I need a prime mover that runs on coal, not on a battery I can only spend once. The Water Turbine and Wind Turbine are out for now: the creek down below is an ice sculpture at twenty degrees Celsius, and both machines take rolled iron plates, a Machine Block, and a motor I cannot make yet.

So today I built a kettle.

Its proper name is the 48V Compact Steam Turbine, paired with a Stone Heat Furnace. Back at the Authority we called this sort of rig a packaged cogeneration unit, though a boiler inspector would have had a fit on the spot. Boiler, governor, dynamo, and air-cooled condenser are all crammed into one iron box.

You can put the parts together on an ordinary bench. Start with an Electrical Motor, hand-crafted from iron ingots and Copper Cable. Combine that motor with two copper plates, a bucket, four iron ingots, and another Copper Cable, and you have the turbine. Any copper plate will do: beat them out by hand if you have a hammer to hand, or roll them on a 48V Plate Machine run off Single-use Batteries. A question of skill, as the old guild manuals used to sniff. The Stone Heat Furnace takes seven stone, a Copper Thermal Cable, and a Combustion Chamber made from four stone laid in a ring.

Placement matters, so do it in order. Set the 48V Compact Steam Turbine down first. It faces you when placed, generator end toward you. Stand in front of it and look to your left: that square of bare metal on the side is the copper heat pad. The Stone Heat Furnace only delivers heat out of its back. Walk around so you are facing that copper pad, then place the furnace flush against it so the back of the furnace sits squarely on the copper. Machines like these pass heat block to block just by touching. No thermal cable between them.

Picture to come: Early steam rig in a timber shed. The back of a Stone Heat Furnace sits flush against the copper heat pad on the left side of a 48V Compact Steam Turbine. Low Voltage Cable runs straight from the turbine's front terminal plate up to a wall-mounted Lamp Socket in Cable mode holding a lit 48V Carbon Incandescent Light Bulb, with no Ground Cable on the line.

Next, fill the boiler. Right-click the turbine with buckets of water. The tank holds four buckets, 4000 mB in all, and accepts another bucket whenever there is 1000 mB of room. Later on you can pipe water into the top flange: an Electrical Age water pipe feeds a built-in float valve that tops the tank up to 3000 mB, and other water pipes work too. Crouch while looking at the turbine casing to see every gauge line, water level included.

Now wire it, and learn from my first blunder of the day. I laid a Low Voltage Cable kit from the turbine's front terminal plate—the back plate works just as well—up to the Lamp Socket on the rafters, flipped to Cable mode. Then, out of sheer muscle memory from yesterday's battery, I staked a Ground Cable onto the line.

I dropped coal into the furnace. A brand-new Stone Heat Furnace starts on Taking fuel, so it eats coal or charcoal straight away; the toggle inside switches between Taking fuel and Declining fuel. Each coal holds 200 kJ. The fire takes roughly thirty seconds to kindle. Its air damper answers the slider in a few seconds, but the coal bed takes a good three minutes to spread into a bigger fire, and with the damper shut it smoulders for minutes before it sinks to embers.

Five minutes later the flywheel was spinning, the turbine was warm, and the lamp above my head was stone dead. I touched the wire with my new MultiMeter.

0.58 V.

Half a volt. I stood there glaring at the casing until it clicked. Yesterday's battery had a minus terminal that needed tying to earth. The turbine does not. Its output is already referenced to ground inside the iron body. Putting a Ground Cable on a turbine line is a dead short straight into the dirt.

I yanked the Ground Cable back out of the floorboards. The lamp snapped bright, and the MultiMeter climbed to 50.4 V. Never stake a Ground Cable onto a Compact Steam Turbine's output. The step-by-step layout is written up in the reference notes.

That should have been the end of a tidy afternoon. Instead, I hooked my first heavy workshop load onto the same wire beside the lamp, threw the switch, and watched the shed plunge into near-darkness. The 25 W carbon filament sank to a dull orange thread.

I probed the line again. The voltage sags until the load takes no more than the boiler can give, so what you read depends on the load:

25.3 V. 62 W.

Sixty-two watts! The firebox was glowing cherry-red behind its grate. Why was the voltage collapsing to half of rated? I crouched beside the turbine and read the status line along the bottom of its readout:

short of heat: a hotter fire (more combustion chambers, if the furnace has room) or less load

What that message and its neighbours mean is listed under reading the gauges. At twenty-five volts, a 48 V 25 W carbon bulb only draws about 6.5 W—dim enough that it stops keeping monsters out of the yard. I cut the workshop load so the lamp could burn bright for the night, and went to bed muttering at the ceiling.

Day 5 — Stability at the fencepost: 71%

I drank a cup of chicory coffee this morning and apologized to Carnot.

Here is the trap that catches everyone first time round, Kid: you think temperature is the same thing as heat. It is not.

Picture filling a bathtub from a jug. Temperature, in degrees Celsius, is how high you hold the jug above the tub. Heat flow, in Watts, is how wide the spout is—how much water actually pours out every second. A candle flame is a thousand degrees Celsius. Try boiling a stew pot over one birthday candle and tell me when supper is ready.

A bare Stone Heat Furnace burns a 1 kW fire. Twenty percent of that heat goes straight up the flue, so only eighty percent heats the furnace, and the stone shell sheds a bit more to the room before the rest crosses into the boiler.

Now look at the 48V Compact Steam Turbine. Its efficiency is 10%. Write that yardstick across the front of your notebook, because we will judge every heat engine in this ledger by the same rule: out of every ten watts of heat that enter the boiler, one watt comes out the wire as electricity and nine watts warm the shed through the air-cooled condenser fins.

The arithmetic is plain and unforgiving:

Picture to come: Stone Heat Furnace interface with 4 Combustion Chambers installed, coal in the fuel slot, an On/Off Regulator in the regulator slot, and the temperature slider set to 350 °C.

I crafted four more Combustion Chambers before noon, slid them into the furnace, and gave the coal bed three minutes to build. By half past twelve the flywheel was a blur and the MultiMeter held 47.7 V at 218 W under load.

The turbine's own governor starts generating at 105 °C and hits full output at 140 °C. When I switched the workshop load off, it did not blow steam or run away; above 150 °C an internal bypass dumps surplus heat straight into the condenser, up to 3.5 kW, so the turbine idled quietly around 155 °C. That bypass still burns your coal if you leave the fire roaring, mind. Above 180 °C a safety valve vents steam and costs water, though a single Stone Heat Furnace cannot push it that high.

Which brings me to the other lesson today nearly taught me the hard way: water and regulators.

The condenser saves ninety-seven percent of the steam, losing just three percent as makeup water. On a bare furnace, one bucket lasts nearly two and a half hours. With four chambers burning, it drinks about 0.37 mB every second—roughly one bucket every 45 minutes, loaded or idle.

If the tank runs dry, the turbine stops making power and stops taking heat. A bare furnace cannot climb hot enough to hurt itself, so it just sits there sulking. A furnace with even one Combustion Chamber at full fire is a different animal: with nowhere for the heat to go—dry boiler or uncoupled back—it climbs straight past 800 °C, burns out in place, and sets the shed alight. You can repair a burned-out furnace with a single Combustion Chamber, though remember that a repaired furnace wakes up on Declining fuel and will refuse coal until you flip the button back. And never tip cold water into a boiling-dry turbine expecting mercy: refilling a hot turbine vents water straight back out as steam until the iron cools below 180 °C.

Do not rely on your memory to keep the tank topped up. Put a regulator in the furnace's regulator slot. Without one, the slider just sets fire strength. With an On/Off Regulator (the 1 % or the 10 % kind; either works)—cheap to make from redstone and iron—the slider becomes a temperature limit from 20 to 1000 °C. Later, once we have macerated sand into silicon for a Cheap Chip, an Analogic Regulator will throttle the fire smoothly and hold the setting within a few degrees, instead of clicking hard on and off. Coupled to a wet turbine, the furnace sits somewhere around 150–170 °C. Set the regulator between 300 and 400 °C. While there is water in the kettle, the fire runs flat out; if the tank ever goes dry, the damper shuts within seconds, the furnace overshoots by a few dozen degrees at most, and the roof over your head is saved. There is also a port on the furnace's left and right sides that takes a 5 V control signal to set the fire from outside, which will matter once we start building real grid controls. All the furnace and turbine numbers are collected in the device table.

Tonight, for the first time since the lower valley froze, the yard stayed quiet. With a proper forty-eight volts on the Lamp Socket above the shed door, the 25 W Carbon Incandescent Bulb burns bright enough to keep the dark at bay—nothing foul can spawn within nine paces of a lit electric bulb, provided you actually feed it the voltage it asks for. Two zombies shambled out of the pines around midnight, squinted into the glare, and turned right back into the trees. It will not stop the Endermen, mind you. Nothing stops the Endermen.

My tidied-up notes for this chapter: Early Heat and the 48V Compact Steam Turbine.


Previous: First Light: Bleeding the Trees · Next: The Signal Processor: A Handful of Chips

Back to the contents