Reference notes for Fire and the Kettle.
Tidied numbers for the kettle plant. Check the table before you stoke it, and check the gauges if the voltage sags or the masonry starts smelling hot.
Your first ~62–220 W of 48 V power before plates, pumps, and high-pressure boilers.
Picture to come: Front isometric view of the bootstrap plant. Left block: Stone Heat Furnace with its back pressed directly to the turbine's left-side copper heat pad. Center block: 48V Compact Steam Turbine facing the viewer. Front or back terminal plate: Low Voltage Cable Kit wired straight to a Lamp Socket with no Ground Cable on the line.
| Device or Parameter | Value / Rating | Behaviour and Failure Limits |
|---|---|---|
| Stone Heat Furnace | 1 kW base fire, 3 kW max | Only 80% of the fire heats the furnace; the rest goes up the flue. Coal or charcoal gives 200 kJ, about 1 min per coal at full 3 kW fire. Kindles in ~30 s. Its air damper follows the slider or regulator in ~5 s; the coal bed takes ~3 min to spread to a bigger fire, and with the air shut it smoulders (3 % of its bed) for ~5 min until it is down to embers. A firebox over ~350 °C lights fresh coal at once. The stone weighs ~600 J/K: about a minute from cold to 250 °C at full fire. Starts on Taking fuel; GUI button toggles Taking and Declining fuel. |
| Combustion Chamber | +500 W fire each | Max 4 chambers in the furnace for 3 kW total fire. Crafted from 4 stone in a ring. Also repairs a burned-out furnace. |
| Furnace Burnout | 800 °C failure | Burns out in place and sets fire nearby. Repair with 1 Combustion Chamber; a repaired furnace starts on Declining fuel. A bare furnace never burns out, but a furnace with even 1 chamber at full fire burns out if the turbine runs dry or is not on the heat pad. |
| Furnace Regulators | 20–1000 °C slider | Without a regulator item, the slider sets fire directly; a wet coupled turbine holds the furnace safe near 150–170 °C on bypass. With a regulator in the slot, the slider sets target temperature. Early choice: an On/Off Regulator (1 % or 10 %) from redstone and iron. An On/Off overshoots its setting by ~25 K when the load goes. The Analogic Regulator is a tuned PID that settles on the setting within a few kelvin; it needs a Cheap Chip from macerated sand, so later. Set 300–400 °C when coupled: full fire normally, throttled back if water fails. A 5 V signal on the furnace's left or right side can also set the fire externally. |
| Thermal Insulation | Halves shell loss | Crafted from 4 wool and stone. Consumes 1 insulation item whenever the furnace exceeds 520 °C. |
| 48V Compact Steam Turbine | 50.4 V max, ~62–64 W bare, ~218–220 W upgraded | Converts 10% of received heat to electricity, capped at 300 W; one Stone Heat Furnace cannot reach 300 W. Power begins at 105 °C and reaches full output at 140 °C. Built-in condenser bypass opens above 150 °C up to 3.5 kW at the cost of fuel; idle sits near 155 °C. Safety valve vents water above 180 °C, unreachable on one stone furnace while wet. Grounded internally; no Ground Cable. |
| Turbine Water Use | 4000 mB tank, 3% makeup loss | Holds 4 buckets; accepts a bucket with 1000 mB free. Top flange takes EA pipes refilling to 3000 mB via float valve, or another mod's water pipes. Loses ~0.37 mB/s with 4 chambers, about 45 min per bucket loaded or idle, and ~2.4 h per bucket bare. Dry: zero power and zero heat draw. Refilling above 180 °C vents water until below 180 °C. |
| Lamp Socket | 48 V load | Defaults to wireless Lamp Supply mode; switch to Cable in the GUI when wired directly. A 48V Carbon bulb draws 25 W at 48 V and suppresses monster spawns within 9 blocks only while lit; dim, starved bulbs do not stop spawns, and Endermen and Withers ignore light. |
| Wind Turbine | 48 V nominal, 57 V max | Later tech: needs iron plates, a Machine Block, and an Electrical Motor. ~160 W at 10 m/s, 4-block tall multiblock, scales by min(y, 100)/100, needs a clear 15×5×5 air box. Cannot fail. |
| Water Turbine | 48 V nominal, 57 V max, 30 W | Later tech: needs iron plates, a Machine Block, and an Electrical Motor. Needs flowing water 1 block out and 1 block down from the front; boosts up to ~3× in local rain. Cannot fail. |
What the Jade lines and meter readings mean when something goes sideways:
short of heat: a hotter fire (more combustion chambers, if the furnace has room) or less load: Your loads want more power than the furnace can supply, so output voltage sags. On a bare furnace at 62 W, voltage can drop to ~25 V, starving a 25 W 48V Carbon bulb down to ~6.5 W; a dark bulb will not keep monsters off. Add Combustion Chambers up to 4, check the fire and fuel, or cut load.Ambient: XX °C: Shown on thermal blocks when you sneak for full Jade lines. Devices cool toward local biome and depth temperature, so hotter biomes trim your cooling margin.