H Copper Cable · A vanilla anvil · p iron plate · M Advanced Machine Block · i iron ingot · _ empty
Capacitor Cell
d p d
d R d
d p d
d Dielectric · p copper plate · R redstone block
Capacitor Bank
C C C
C C C
p H p
C Capacitor Cell · p iron plate · H Copper Cable
Total for one Capacitor Bank: 36 Dielectric, 6 redstone blocks, 12 copper plates, 2 iron plates, and 1 Copper Cable.
The electrical anvil
A workshop desk that repairs tools for no XP.
Slots: damaged tool in the left slot; its repair material or a plain unenchanted copy of the same tool in the right slot. Enchanted books and enchanted items are refused in the material slot. Items whose bar shows charge cannot be mended here.
Units and credit: one unit of material repairs a quarter of the tool. Partial units stay in the desk as credit for that material, and the next tool uses them. Breaking the desk loses stored credit.
Anvil penalty: each repair step drops the penalty one vanilla notch along 31 → 15 → 7 → 3 → 1 → 0 and never raises it. The floor depends on how many enchantments the tool carries.
Engraving: type a name and press Enter for a 2 kJ pulse. A blank name clears the label.
Power: one 400 V connection on the plate low on the back. The desk acts as a 32 Ω load, drawing 5 kW at 400 V and less as the line sags: P = U² ÷ 32. It burns above 520 V, 1.3× its rating.
Burst cycle:20 kJ per burst, about 4 s on a stiff 400 V line. One unit of material takes 2 bursts, 40 kJ total. Between bursts it rests at least 3 s.
Start and pause: starts a burst at 380 V, or at 372 V once the line has held level for 2 s. Below 360 V it pauses with progress kept and holds off for 1 s.
Status messages
Message
Where
Meaning
Waiting for 380V (now xV)
Screen, Jade
Ready to weld; waiting for 380 V, or 372 V level for 2 s.
Supply too weak (xV): paused
Screen, Jade
Voltage dropped below 360 V mid-burst. Progress is saved; holds off 1 s.
Between bursts: waiting for 380V (now xV)
Screen, Jade
Resting at least 3 s and waiting for line voltage to climb back.
Welding
Screen, Jade
Arc active, drawing up to 5 kW.
Put a tool on the bench
Screen, Jade
Left slot is empty.
Needs its repair material
Screen, Jade
Right slot needs the matching repair material or an unenchanted copy.
Repaired
Screen, Jade
Tool is at full durability.
This can't be mended here
Screen, Jade
Item cannot be repaired here, or the material slot holds an enchanted item.
No material credit / Credit: ...
Screen only
Stored fraction of repair material remaining inside the desk.
Anvil cost N (lowest M), no XP needed
Screen only
Current vanilla penalty N and the lowest notch M its enchantments allow.
Why a peak load is hard
Energy is power × time. A 1 kW plant makes 40 kJ in 40 s, enough for a unit every minute. The desk demands 20 kJ in 4 s. Push a small generator past its rating and the line sags below 360 V the instant the arc strikes. Size the generator for the average load and put a local store beside the desk for the peak.
Store
Good for
Bad for
Lead-acid battery
bulk energy, keeps for days
fast pulls wear it; 230 V maximum
Capacitor Bank
one full 20 kJ burst at 400 V
leaks; flat by morning
Power Capacitor
small bursts at high current
tiny usable store; leaks
Power Inductor
smoothing current swings
stores almost no energy
The Capacitor Bank
One bank carries one 20 kJ burst and finishes near 364 V.
Ratings:1.44 F, rated 500 V, ESR 0.1 Ω.
Limits and repair: explodes above 650 V or above 75 K over ambient temperature. Repair a burnt bank with a Dielectric.
Usable store: holds 115 kJ at 400 V. Between 400 V and 360 V, 21.9 kJ is usable by the desk.
Wiring: polar. Connect + on the left flank of its front, HV band, to the desk's 400 V line. Connect − on the right flank, black band, to a Ground Cable.
Inrush: nothing inside limits current. Connecting an empty bank straight to a stiff 400 V line pulls enough current to burn the cable. Always charge through a rheostat; see charging the bank.
Leakage: RC time constant of 1800 s, about 1.25 kΩ or 128 W at 400 V. Roughly 2% remains after an hour, so it is flat by morning. Keep the plant connected.
Jade shows live voltage, energy, and capacitance.
Charging the bank
Put a Large Rheostat in series between the 400 V plant and the bank. Coal Dust count sets its nominal resistance, and its control signal scales resistance from about 0.8 Ω at no signal up to nominal at full signal.
Load 23 Coal Dust into the Large Rheostat for 82 Ω nominal.
Wire and set the signal first. Apply full signal before connecting an empty bank so it starts at 82 Ω. With no signal, the rheostat sits near 0.8 Ω — effectively a stiff line that burns the cable on an empty bank.
Charge from empty at 82 Ω. Left at 82 Ω, the bank's leak parks it near 375 V.
Lower the signal past ~300 V to bring resistance down to about 25 Ω. At 25 Ω the bank settles near 392 V against its leak and refills cleanly between bursts.
Run the desk: wire 400 V to the desk's back plate with the charged bank beside it, + to the line and − to ground. Place tool left and material right. The desk starts at 380 V, or 372 V after 2 s level, welds 20 kJ, rests at least 3 s, and repeats. Leave the plant connected so the bank does not bleed down.
Cautions:
Never connect an empty bank straight onto a stiff 400 V line, and never start from empty at 25 Ω or with the rheostat signal unpowered.
Heat: charging any capacitor through resistance turns about as much energy into heat in the resistor as the bank stores — roughly 115 kJ from empty. Expect the rheostat to run hot.
A Power Inductor in series with the rheostat smooths the plant's draw while the bank refills after each burst.
The Power Capacitor
The smaller, earlier wall capacitor.
Redstone in the left slot, 1 to 13, sets capacity. Each Dielectric adds 48 V of rating while dividing capacity by the square of the Dielectric count. Maximum stored energy at full rating is 11.5 kJ with 13 redstone.
For a 400 V line, load 9 Dielectrics for a 432 V rating, popping above 562 V.
Between 400 V and 360 V, less than a fifth of its store is usable — about 1.9 kJ each. One 20 kJ burst takes about eleven of them.
Wiring: terminals are the two ends of the can, one to the line and one to a Ground Cable.
Leaks on the same timescale as the bank.
Sizing
One Capacitor Bank per desk carries one burst. Refill speed depends on plant output and the rheostat setting; see charging the bank.
Weak plant: a few hundred watts still works as long as output beats the bank's ~128 W leak at 400 V. The desk welds in shorter bites as voltage recovers.
No bank: the plant must hold 360 V or more under the full 5 kW draw.
Stored energy is E = ½ × C × U². Desk draw falls as voltage sags via P = U² ÷ 32 Ω. Cable resistance drops a few volts along the run, so the supply end reads slightly above 360 V when the desk pauses.
The Power Inductor
Copper Cable, 1 to 19, sets inductance from 0.1 H to 100 H. It requires a Ferromagnetic Core; without one it is an open circuit. It cannot burn.
Stores almost nothing and resists changes in current. Wired in series with the charging rheostat between plant and bank, it lets the bank absorb each weld shock while the plant sees a steadier refill draw.
Cannot tame an empty bank on its own: without resistance, current swings hard and voltage rings past the bank's 650 V limit.
Alone, without a capacitor, an inductor makes a pulse load worse by holding current back right when the desk demands it.