Boilers, Pressure, Condensers and the Regulator

Reference notes for The Real Steam Plant. Kept short so you can read them while a pipe is already whistling.

The boiling-point table

In a closed boiler holding both water and steam, pressure and boiling temperature are locked together. Water cannot reach a pressure until it reaches that boiling point, and if nothing takes steam out, pressure climbs until it matches the fire. Jade percentages below are Jade's pressure efficiency, not thermodynamic efficiency; see thermodynamic efficiency.

Absolute Pressure Boiling Temp, °C Plant Milestone
0.04 bar ~29 °C Condenser vacuum at part load; near air temperature, ~201% on Jade.
0.1 bar 46 °C Condenser vacuum at full rated load.
1 bar 100 °C Boiling begins; boiler starts producing steam.
2 bar 120 °C Where an unregulated turbine collapses the boiler; Jade 29% to open air.
5 bar 152 °C Floor for the "Under Pressure" advancement: loaded under 5 bar for 30 s triggers it.
6 bar 159 °C 48V Submersible Pump shut-off. Flow drops linearly to 0 mB/s here.
10 bar 180 °C 48V Steam Turbine rated inlet. Jade 100% to open air.
15 bar 198 °C 230V Submersible Pump shut-off and condenser pump rating. Jade 119% to open air.
18 bar ~207 °C Condenser return pump shut-off.
20 bar 212 °C Iron Pipe working limit and HP Steam Turbine operating pressure.
25 bar 224 °C Iron Pipe burst and 48V Steam Turbine casing burst. Above 25 bar, the turbine explodes.
60 bar ~276 °C HP Steam Turbine casing burst.
100 bar 311 °C Alloy Pipe working limit. Bursts at 300 bar.
350 bar — Boiler shell burst. Pipes and turbines fail long before this.

The furnace-regulator trap: With no electrical load, the turbine governor shuts its valve and boiler water climbs straight toward your furnace set point.

Capping furnaces at ~200 °C stops the boiler passing ~15.5 bar, but starves output at 10 bar down to ~7% under load. Running hotter at 230–250 °C moves real heat, provided you fit a Pipe Safety Valve.

Thermodynamic efficiency

Jade's pressure efficiency measures work per gram of steam compared to a 10 bar turbine venting to open air. It is not fuel-to-watts efficiency.

Inlet Pressure Boiling Temp, °C Jade Pressure Eff., Open Air Notes
2 bar 120 °C 29% Unregulated collapse pressure.
4 bar ~144 °C ~60% Still below the 5 bar advancement floor.
10 bar 180 °C 100% Rated 48V inlet; ~201% on Jade condensing at 0.04 bar.
15 bar 198 °C 119% Upper edge before 230V pump shut-off.

The three-part control rule

  1. Sliders do nothing without a regulator item. Both furnaces and turbines have a regulator slot. Without a regulator item in the slot, a furnace ignores its temperature set point and a turbine acts as a plain throttle, letting the boiler collapse to ~2 bar.
  2. The turbine regulator holds the pressure floor. Put an Analogic Regulator — crafted from 2 redstone, a Cheap Chip, and an iron ingot — in the turbine's regulator slot. Set "Hold the inlet at: X bar", adjustable from 1 to 25 bar in 0.5 bar steps, default 10 bar. The valve stays shut until inlet pressure reaches the set point, then passes steam, giving 700–800 W at 10 bar in testing. Do not set the target higher than your furnace temperature can boil, or the valve never opens.
  3. The safety valve caps the pressure ceiling. Furnace regulators set to 230–250 °C give strong heat transfer under load, but will burst an unloaded plant without relief. Fit a Pipe Safety Valve set to 15 bar on the steam pipe to bleed excess pressure safely whenever load drops. Set lower, it vents steadily at idle, costing coal and water: the furnace regulators hold the furnaces' temperature, not the boiler's, and nothing throttles the fires for you. If it still vents at 15 bar, turn the furnaces down while idle, or control them from a Thermal Probe on the boiler through a Signal Processor.

Firing the boiler

Plumbing and hardware

Boiler

Crafted from 5 iron ingots, a bucket, a cauldron, and a Copper Thermal Cable. Holds 8 buckets, or 8,000 mB; fill by hand with water buckets on cold start.

Steam turbines

48V Steam Turbine: Crafted from an Electrical Motor, Machine Block, 2 iron ingots, rubber, and Copper Cable. Rated 1,000 W.

HP Steam Turbine: Larger tier turbine rated 16 kW at 20 bar, with a casing burst at 60 bar. Steam enters through an EA pipe on its top port, and exhaust leaves out the back. Pairs at higher tiers with an LP Steam Turbine and a Plant Condenser.

Condensers

Small Steam Condenser: Crafted from EA iron and copper plates, a Machine Block, and an Electrical Motor. A larger Plant Condenser exists for HP/LP installations.

Pipe safety valve

Boilers have no built-in relief. Fit a Pipe Safety Valve, crafted from a Pipe Valve — 2 EA iron plates and a lever — plus a gold nugget and an iron nugget.

Jade fluid readouts

Jade displays steam mass in grams (g), flow in grams per second (g/s), and pressure labelled by medium, such as 10.0 bar of steam, alongside pressure efficiency relative to 10 bar open-air operation.


Reference index · Back to the contents